GEKKO - battery-powered data logger
GEKKO – battery-powered data logger is particularly flexible in use as it connects to many devices. E.g. it perfect for overflow registration.
ACOWA´s GEKKO - Battery-powered data logger
The GEKKO battery-powered data logger is used in water applications such as H2S detection, level measurement as well as overflow registration. It offers numerous benefits, due to its robust IP 67 industrial design and versatile capabilities. Below are the key advantages of using GEKKO.
Replaceable modules for future technology
Firstly, GEKKO’s communication modules are mounted on separate boards, allowing for easy adaptation to future communication technologies without replacing the entire data logger. Whether it’s 4G, 5G, or other emerging technologies, GEKKO can be upgraded to support the latest communication standards.
The GEKKO - battery-powered data logger is highly portable
Secondly, the GEKKO is compact and lightweight, making it highly portable. Its battery-powered operation eliminates the need for external power sources, allowing you to easily move and deploy the data logger in remote locations.
Furthermore, GEKKO has flexible power options. It can be powered by either 2 D-size lithium batteries, which can be inserted either directly into the unit or offered as an external battery pack. However, GEKKO also provides the flexibility for an external 12-30V DC power source, which enables the use of solar cells, wind turbines, water turbines, or similar options.
Future-Proof Communication with GEKKO
Thirdly, GEKKO has the capability to gather data and record signals of various kinds via external standard 4-20mA equipment. This versatility makes it ideal for applications such as H2S detection, measuring levels, temperature, and pH, as well as capturing stormflow patterns and precipitation data.
The GEKKO also empowers users to define customized logging and call intervals. Thereby optimizing its functionality for specific application needs. In addition, the system features an event-driven logging function, which allows for heightened logging and call frequency based on analog limits or digital inputs.
Communication on GEKKO - battery-powered data logger
Fourthly, GEKKO has flexible communication capabilities. It supports RS485 MODBUS communication, allowing easy integration and data exchange with external devices and systems.
Additionally, it can communicate via standard MODBUS TCP/IP or SMS commands. The data logger is equipped with a 4G modem (2G, 3G, and 4G) or a Sigfox modem, providing reliable and flexible communication options for remote monitoring.
Easy connectivity to visualization platforms
Lastly, data generated by GEKKO can be effectively visualized through SCADA-systems, AcowaCore as well as other third-party software platforms. For easy setup simply connect via a USB cabel using the free configuration tool: AcowaZoo. Or alternatively connect wirelessly to AcowaCore.
Read more about the GEKKO
Last but not least, for more info about GEKKO in a country near you, go to our agents page and connect to: Agents with GEKKO
Additionally, for danish speaking people – feel free to visit wasys.dk/gekko/
SPECIFICATIONS
GEKKO has the following general specifications as outlined below:
(NOTE! GEKKO is not EX-classified and must not be installed in EX areas)
Dimensions | L=186mm, W=156mm, H=60mm |
Weight | 620g without batteries |
Wire connection | 0.5–2,5 mm2 |
Vibration (sinusoidal) | 10-500Hz, 1G |
Free fall drop | 30 cm |
Enclosure class | IP67 |
Power supply | 12V DC – 30V DC |
Batteries | 2 x Lithium SAFT |
Humidity | Humidity 10% – 95% non-condensing air |
Operating temperature | -20°C to +50°C |
Storage temperatur | -20°C to +60°C |
Functional height | Max. 2000m above sea level |
Start-up time total | 20-120 sec. (depending on GSM network) |
Output voltage | 15V DC |
Output current | Max. 100mA |
Tolerance | +/- 20% |
Number of analog mA inputs | 4 |
Electrically insulated | No |
Measuring range | 0/4–20mA |
Input impedance | Approx.100Ω |
Measurement accuracy | Better than 0,5% of FS |
Signal range | 0-24mA / 0–30V DC |
Cable/signal length | Max. 100m |
Number of digital inputs | 2 |
Electrically insulated | No |
Digital signal | Low < 5V / < 1mA High > 12V / > 4mA |
Analog signal measuring range | 0–10V DC |
Analog signal impedance | Approx. 20KΩ |
Measurement accuracy | Better than 1% of FS |
Signal range (min/max.) | 0–30V DC |
Cable/signal length | Max. 100m |
Item number | Description |
---|---|
1772-2204000 | GEKKO 4G. |
1772-2204100 | GEKKO SIGFOX. |
UHR-13Ah | Lithium SAFT 3,6V battery |
1717-0B24-C884G | Quad band antenna (2G, 3G, 4G) w angle connector |
Sigfox-U | 5 year SigFox subscription incl. creation on Sigfox back-end as well as invoice handling. |
The GEKKO data logger is used in applications, such as:
- Overflow registration
- Hydrogen sulfide measurement
- PH measurement
- Pressure measurement
- Level measurement in wells
- Level measurement in streams and rivers
- Level measurement in reservoirs and tanks
- Collection of rainfall data
- Groundwater monitoring